<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xmlns:xlink="http://www.w3.org/1999/xlink">
	<front>
		<journal-meta>
			<journal-title-group>
				<journal-title>Tạp chí Khoa học và Công nghệ</journal-title>
				<abbrev-journal-title>Khoa học &amp; Công nghệ</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="ppub">2615-9015</issn>
			<issn pub-type="epub">2615-9015</issn>
			<publisher><publisher-name>Trường Đại học Nguyễn Tất Thành</publisher-name></publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="publisher-id">8484d9ce-35c7-8dc2-817a-01a0fbbd8a96</article-id>
			<article-id pub-id-type="doi">10.55401/cx99ke11</article-id>
			<title-group><article-title>Determination of norfloxacin, cipfloxacin, levofloxacin and moxifloxacin in urine by HPLC with a two-channel fluorescence detector</article-title></title-group>
			<contrib-group>
				<contrib contrib-type="author"><string-name>Nguyen Nguyen Truong</string-name></contrib><contrib contrib-type="author"><string-name>Nguyen Thi Minh Diep</string-name></contrib><contrib contrib-type="author"><string-name>Vu Anh Tuan</string-name></contrib>
			</contrib-group>
			<pub-date pub-type="epub"><day>17</day><month>3</month><year>2024</year></pub-date>
			<volume>6</volume>
			<issue>4</issue>
			<fpage>8</fpage>
			<lpage>8</lpage>
			<self-uri content-type="html" xlink:href="https://jst.ntt.edu.vn/articles/8484d9ce-35c7-8dc2-817a-01a0fbbd8a96" />
			<self-uri content-type="pdf" xlink:href="https://uploadservice.ntt.edu.vn/dbOBrwZN1R_1/file/determination_of_norfloxacin_261002-na-h8qCHVYeF.pdf" />
			<abstract><p>A sensitive HPLC-FLD method with two-channel fluorescence detection was established and validated for quantification of four fluoroquinolones (norfloxacin, ciprofloxacin, levofloxacin and moxifloxacin) in urine samples. The fluorescent detector was set at two-channel excitation and emission wavelengths: 280/445 nm (for NOR, CIP) and 290/500 nm (for LEVO, MOXI). The measurement protocol was in compatible with both of the sample treatment procedures including the liquid-liquid extraction (LLE) and solid-phase extraction (SPE). The method was well-validated with the limit of quantification: 0.027; 0.034; 0.024; 0.020 µg/mL (for LLE), and 0.028; 0.033; 0.024; 0.020 µg/mL (for SPE) for NOR, CIP, LEVO, MOXI, respectively. The method has been proved to be precise and accurate, with the relative standard deviation lower than 3% and the recovery ranging from 98.0%¸102.0%, for all fluoroquinolones. The proposed HPLC-FLD method provides an alternative approach for the simultaneous analysis of fluoroquinolones in urine.</p></abstract>
			<kwd-group><kwd>fluoroquinolones</kwd><kwd>urine</kwd><kwd>two-channel excitation and emission</kwd><kwd>HPLC-FLD</kwd></kwd-group>
		</article-meta>
	</front>
</article>